INSTALLER GUIDE
14. This appliance is supplied with a flue restrictor for use where the flue draught is
excessive. The restrictor must NOT be fitted
where a precast flue or a flue liner is used. For
all other installations the restrictor should be
fitted. There may however, be certain
exceptional circumstances where fitting the
restrictor causes the fire to fail the spillage test.
In such cases the restrictor will have to be
removed. After removal conduct the spillage
check again.
The restrictor is packed loose with the
appliance and is fixed with two screws (See
Figure 14. Flue restrictor
figure 14). The restrictor has two
location holes and a notch along one
edge. It is important that the notch is
positioned to the top (See figure 14).
15. There is a length of self adhesive
foam seal supplied with the fire. This
will need to be fitted to the outer rear
edges of the side and top flanges of the
hotbox. Cut a 485mm length of foam
seal. Be careful not to stretch the seal
when measuring. Remove the protective
backing from the foam seal and fit this
to the rear of the top flange (See figure
15). Cut two 580mm lengths. Fit these
to the rear outer edges of the side
flanges. Ensure that there is no gap
between the foam seals where they meet
Figure 15. Fitting the foam seal
at the top flange (See figure 15).
Page 20
©