position and test around the sealing screw for gas
soundness with a suitable leak detection fluid.
11.5 Fitting the lower hotbox baffle.
The lower hotbox baffle is supplied for use when
fitting the appliance into elevated builders
openings or 'Hole in the wall' installations.
1. Locate the baffle behind the control knob
bracket as in figure 25.
2. Secure the baffle using the screw supplied.

12. FITTING THE CERAMIC FUEL EFFECT

The installer and owner guide for the ceramic fuel effect is supplied with the ceramic
fuel effect. It is important that the guide for the ceramic fuel effect be placed inside or
attached to this guide and handed to the customer following completion of the 'final
review' section.

13.1 Check the handset and burner operation.

Repeat the checks conducted in section 11.3.1 to 11.3.3.
Please note:
When first turned on from cold, the flames will appear predominantly blue.
When operating the fire for the first time, some vapours may be given off which could
set off smoke alarms in the vicinity. These vapours are quite normal with new
appliances. They are totally harmless and will disappear after a few hours use.

13.2 Check for spillage.

A spillage check must be made before leaving the installed appliance with the
customer. Make this with all the ceramic fuel effect pieces in position.
1. Close all doors and windows in the room containing the appliance.
2. Light the appliance and set the control to the 'High' position.
3. Leave the appliance on for five minutes.
©