5. Detach the injector pipe.
6. Remove the thermocouple by unscrewing the
thermocouple nut at the gas valve.
7. Remove the wiring plug from the top of the motorised
head. To do this push the tab in the top of the connector
and lift the connector clear of the head. Always hold the
connector body when removing. Never pull on the wires
(See figure 38).
7. Remove the two screws securing the gas valve to the
mounting bracket.
8. Remove the gas tap
9. Refit in the reverse order.

16.5 To grease the control tap.

1. Detach the tap as in section 16.4.
2. Remove the two screws amd washers from the
head of the tap. Before removing the motorised
head please note the location of the head as it is
posible to fit it upside down.
3. Clean and grease the plug lightly with suitable
grease. Do not apply excessive grease. Particularly,
make sure that the gas ports in the tap are not
restricted by grease.
4. Fit the head back onto the tap body. There is a
circular flat on the tap body. The wire connector
should face this side of the tap.
5. Fit the screws and washers removed previously.
6. Fit the tap in the reverse order to that shown in
section 16.4 points 1- 8.

16.6 To remove the main burner and injector.

(See figure 39 & 40).
1. Remove the burner unit (See section 16.2).
2. Support the elbow injector and unscrew the
injector nut.
3. Remove the two screws from the burner clamping
plate (See figure 39)
4. Lift the right hand side of the burner, slide it to the right and lift clear.
5. If removing the injector, remove the burner clamping screw (See figure 40) and
unscrew the injector from the burner
©