Sungrow SG30CX User Manual page 60

Pv grid-connected inverter
Hide thumbs Also See for SG30CX:
Table of Contents

Advertisement

5 Electrical Connection
step 3 Loosen the swivel nut and select an appropriate seal according to cable outer diameter.
Lead the cable through the swivel nut, and seal successively.
O O u u t t e e r r D D i i a a m m e e t t e e r r D D
( ( m m m m ) )
4.5 ~ 6
6 ~ 12
12 ~ 18
step 4 Insert the RJ45 connector to the RJ45 jack.
step 5 If other wiring operations need to be performed on the communication board, finish the
wiring operations before performing the following steps. If otherwise, continue to per-
form the following steps.
step 6 Install the junction box, see
step 7 Pull the cable gently to make sure it is secured, tighten the swivel nut clockwise.
50
S S e e a a l l
c
a + b
b
" Install the Junction
Box".
User Manual