Connecting The Battery - Yamaha F200 Owner's Manual

Hide thumbs Also See for F200:
Table of Contents

Advertisement

Available languages

Available languages

3.
Check the battery connections. They
should be clean, secure, and covered by
an insulating cover. WARNING! Bad
connections can produce shorting or
arcing and cause an explosion.
EMU35496

Connecting the battery

EWM00573
WARNING
Mount the battery holder securely in a dry,
well-ventilated, vibration-free location in
the boat. Install a fully charged battery in
the holder.
ECM01125
NOTICE
Do not reverse the battery cables. Other-
wise, the electrical parts could be dam-
aged.
1.
Make sure the main switch (on applica-
ble models) is "
on the battery.
2.
Connect the red battery cable to the
POSITIVE (+) terminal first. Then connect
the black battery cable to the NEGATIVE
(-) terminal.
3
1. Red cable
2. Black cable
3. Battery
[EWM01913]
" (off) before working
1
2
ZMU01811
3.
The electrical contacts of the battery and
cables must be clean and properly con-
nected, or the battery will not start the
engine.
Connecting an accessory battery (optional)
If connecting an accessory battery, consult
your Yamaha dealer about correct wiring. For
the fuse size, see ABYC (E-11).
Single engine
3
1. Isolator leads with circuit protection
2. Red cable
3. Black cable
4. Fuse
5. Battery for accessories
6. Battery for starting
7. Negative connecting cable
Maintenance
2
1
4
6
5
7
ZMU05939
92

Advertisement