Event Module (Marker Number); Warning Module - Pepperl+Fuchs PXV F200-B17-V1D Series Manual

Data matrix positioning system
Hide thumbs Also See for PXV F200-B17-V1D Series:
Table of Contents

Advertisement

PXV...-F200-B17-V1D
Operation and communication
5.1.5.6

Event Module (Marker Number)

Size
1 word,
consistent
Data type: Unsigned16
Value range: 0 ... 999
Example: Event number 1 is the current event number.
Module ident number: 0x00000017
Submodule ident number: 0x00000107
5.1.5.7

Warning Module

Size
1 word,
consistent
Data type: Unsigned16
Value range: See table below
Module ident number: 0x00000018
Submodule ident number: 0x00000108
Warning Data Set
Bit no.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Table 5.1
Type
Input data
Type
Input data
Con-
tent
Word 1
Description
WRN01 A code with non-PXV content was found.
WRN02 The read head is too close to the Data Matrix code tape.
WRN03 The read head is too far from the Data Matrix code tape.
WRN04 Y position too large. The sensor is just before OUT.
WRN05 Y position is too small. The sensor is just before OUT.
WRN06 The read head is rotated or tilted in relation to the Data Matrix code tape.
WRN07 Low level of code contrast.
WRN08 Repair tape detected.
WRN09 Temperature too high.
WRN10 Reserved
WRN11 Reserved
WRN12 Reserved
WRN13 Reserved
WRN14 Reserved
WRN15 Reserved
WRN16 Reserved
If no warnings are present, all bits in the warning data set are set to 0.
Content
Last event marker
Last event number
Content
Last warnings
Last warning number