Password Menu; Test Menu - Rice Lake 482-AG Technical Manual

Livestock digital weight indicator
Table of Contents

Advertisement

482-AG Livestock Digital Weight Indicator
3.4

Password Menu

The Password menu is used to set or edit passwords.
CONFIG
Parameter
Settings
CNFG
000000
The configuration password, if enabled, is used for electronic sealing of the indicator. Once a configuration password has
been set, the existing configuration password is required before the password can be edited. Entering this menu requires
0
999998
the configuration switch to be pressed. 000000 = no password
000000
USER
The user password, if enabled, restricts access to the serial and print formatting menus. Once a user password has been
entered, the existing user password is required before the password can be edited. 0000000 = no password
0
999998
Enter 999999 to reset either password. This reset can also be used in the event a password is forgotten.
IMPORTANT
Entering 999999 will reset the configuration of the scale to default values.
3.5

Test Menu

CONFIG
Parameter
Choices
ADTEST
Displays raw A/D counts
NWGMNT
TOTAL
The number of weighments that exceed value set in WGMNST
OVECAP
The number of weighments that exceed the capacity of the scale as set in the config and format menus, see
on page 18
WGMNST
0–999999
Weighment Threshold – sets the weight threshold over which WGMNST/Over value will be counted
DEFLT
Resets all parameters to factory defaults; at DEFLT, press GROSS/NET, indicator will display SAVING and cycle power
www.RiceLake.com
26
Visit our website
FORMAT
CALIBR
PROGRM
Figure 3-6. Password Menu
Table 3-8. Password Menu Parameters
FORMAT
CALIBR
ADTEST
Figure 3-7. Test Menu
and
Section 3.1.3 on page 22
Table 3-9. Test Menu Parameters
PASWRD
TEST
CNFG
USER
Description
PROGRM
PASWRD
NWGMNT
WGMNST
TOTAL
OVERCAP
Description
MENU
TEST
MENU
DEFLT
Section 3.1

Advertisement

Table of Contents
loading