3.0 Setup Menu

This section describes the various setup parameters for the 1280 FlexWeigh Concrete Batcher. Detailed descriptions of the
Scale Configuration, Communications, Features, Formats, Digital I/O, Analog Output, Setpoints and Diagnostics menus are
provided in the 1280 Enterprise Series Technical Manual (PN 167659).
3.1
Setup Menu
To enter the setup menu.
1. Press
in the bottom right corner of the main display to enter the setup menu.
Setup
The Setup menu offers access to the following:
Item No.
Selection
1
Setup Password
2
DIO Test Screen
3
Global Settings
4
Water Settings
5
Mix Design Database
6
Customer Database
7
Import/Export
8
Clear Transaction Database Clear the database for all transactions by selecting Yes or No
9
Reprint Transaction
10
Admixture #1 Settings
11
Admixture #2 Settings
12
Admixture #3 Settings
13
Admixture #4 Settings
14
Scale #1 Settings
15
Scale #2 Settings
16
Scale #3 Settings
17
Scale #4 Settings
18
Scale #5 Settings
1
5
2
6
3
7
4
8
9
Figure 3-1. Concrete Batcher Setup Menu
Modify the system password. Setting password to 0 disables the system password.
Test each Digital I/O on the 1280 FlexWeigh Concrete Batcher
Edit Max Batch Size, Conveyor Runout, Units Mode, Ticket Number, Language Button (allows user to switch
between primary and secondary languages, Scale Configuration and Moisture Compensation)
Edit Discharge (Before Discharge, During Discharge), Countby, Tail water %
Add, edit or delete mix designs
Add, edit or delete customers
Import the database or export the database to another device
Select and reprint a previous completed transaction
Edit Name, Type (None, Bottle, Direct), Discharge (Tail Water, Front Water), Countby and Coast for Admixture #1
Edit Name, Type (None, Bottle, Direct), Discharge (Tail Water, Front Water), Countby and Coast for Admixture #2
Edit Name, Type (None, Bottle, Direct), Discharge (Tail Water, Front Water), Countby and Coast for Admixture #3
Edit Name, Type (None, Bottle, Direct), Discharge (Tail Water, Front Water), Countby and Coast for Admixture #4
Edit Names, Free falls, Min flow, Vib/air settings (None, Always, No Flow) and Start Delay for Scale #1
Edit Names, Free falls, Min flow, Vib/air settings (None, Always, No Flow) and Start Delay for Scale #2
Edit Names, Free falls, Min flow, Vib/air settings (None, Always, No Flow) and Start Delay for Scale #3
Edit Names, Free falls, Min flow, Vib/air settings (None, Always, No Flow) and Start Delay for Scale #4
Edit Names, Free falls, Min flow, Vib/air settings (None, Always, No Flow) and Start Delay for Scale #5
Table 3-1. Setup Menu Selections
© Rice Lake Weighing Systems ● All Rights Reserved
10
14
11
15
12
16
17
13
18
Description
Setup Menu
13

Advertisement

Table of Contents
loading

Table of Contents