5.2.13 Sub-FC40(0x28): Set RTC Time

Byte
Description
order
00
Address
01
FC
02
Sub-FC
03
Year_MSB
04
Year_LSB
05
Month
06
Day
07
Hour
08
Minute
09
Second
10
Reserved
Byte
Description
order
00
Address
01
FC
02
Sub-FC
03
Result
ACS-20B(W)-MRTU User Manual
Copyright © 2021 ICP DAS Co., Ltd. All Rights Reserved
Table 5-29: FC100-Sub-FC40 Request
Size
Value
1 Byte
1 ~ 247 (Net ID)
1 Byte
0x64
1 Byte
0x28
1 Byte
High byte of AD Year,
e.g. 07h of 07E5h (2021)
1 Byte
Low byte of AD Year,
e.g. 0xE5 of 0x07E5 (2021)
1 Byte
1 ~ 12
1 Byte
1 ~ 31
1 Byte
0 ~ 23
1 Byte
0 ~ 59
1 Byte
0 ~ 59
1 Byte
0x00
Table 5-30: FC100-Sub-FC40 Response
Size
Value
1 Byte
1 ~ 247 (Net ID)
1 Byte
0x64
1 Byte
0x28
1 Byte
0=>OK, Others=>Error