Sub-Fc44(0X2C): Get Inverted Red/Blue Led Status; 0X2C; Get Inverted Red/Blue Led Status - ICP DAS USA ACS-20B-MRTU User Manual

No-touch infrared sensor switch
Table of Contents

Advertisement

5.2.17 Sub-FC44(0x2C): Get Inverted Red/Blue LED Status

Byte
Description
order
00
Address
01
FC
02
Sub-FC
Byte
Description
order
00
Address
01
FC
02
Sub-FC
03
Inverted
Red/Blue
LED State
ACS-20B(W)-MRTU User Manual
Copyright © 2021 ICP DAS Co., Ltd. All Rights Reserved
Table 5-37: FC100-Sub-FC44 Request
Size
Value
1 Byte
1 ~ 247 (Net ID)
1 Byte
0x64
1 Byte

0x2C

Table 5-38: FC100-Sub-FC44 Response
Size
Value
1 Byte
1 ~ 247 (Net ID)
1 Byte
0x64
1 Byte
0x2C
1 Byte
0 => default Red(Standby) / Blue(Sensing);
1 => Red(Sensing) / Blue(Standby)
Version 1.1