IEMCA VIP 80 Manual For Use And Maintenance page 107

Table of Contents

Advertisement

20
E r r o r : f l a g
ERROR
The short feed flag was not knocked
down.
E r r o r : n o
21
ERROR
The guide channel lifting levers do
not lower.
E r r o r : w o r k p i e c e
22
ERROR
The machining cycle lasted longer
than the time set in parameter 23.
INSTALLATION PROCEDURE
n o t
k n o c k e d
CAUSE
No bar.
l e v e r
l o w e r i n g
CAUSE
During the BAR CHANGE the guide
channel did not lower or the bar
drop control did not switch off.
t i m e
CAUSE
The machining cycle required more
time than set in parameter 23.
The machining cycle was stopped
or slowed down.
45
SOLUTION
Load new bars into the bar feeder
magazine.
SOLUTION
Check the cylinder motion.
Check the lever lifting and channel
lifting sensors.
o u t
SOLUTION
Check the settings of parameter 23
based on the actual work cycle.
Check the effective length of the
work cycle and ensure that it is not
stopped or slowed down.
2
302.061

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents