TROUBLES - CAUSES - REMEDIES
Cause
Bar passage guide adjustment too
high.
Remedy
Adjust bar passage guide to right height.
Cause
Feeder not aligned with lathe.
Remedy
Check and correct alignment.
THE CARRIAGE WON'T COMPLETE ITS PREFEED
STROKE
Cause
The bar is too long.
Remedy
The max. length must correspond to the
max. length contained in the lathe
spindle.
THE BAR PUSHER WON'T REACH THE REAR
END-OF-STROKE
Cause
Excessive flash at bar end.
Remedy
Remove bar flash before feeding.
BAR HAS DIFFICULTIES IN ENTERING LATHE
COLLET
Cause
Wrong setting of the bar pusher
working position.
Remedy
Adjust the bar pusher working position.