Cold Pull Method - Felix printers Pro Series Troubleshooting Manual

Hide thumbs Also See for Pro Series:
Table of Contents

Advertisement

Felix Pro L/XL
Troubleshooting guide
15
December 10, 2019,

6 Cold pull method

Problem: One of the extruders is making a clicking noise or not pushing out the filament?
Cause: It's most likely clogged or partially clogged. Follow this guide to use the cold pull method to fix the
extruder or just to clean it., This is also recommended when switching materials.
Setting the temperature
First we need to set the temperature of the extruder to the of the material that's currently in it, for this example
we are going to use PLA temps or 195°C (383°F) in this case, for PETG and ABS you might want to go a little higher
like 220°C (428° F).
Navigate to the change filament menu.
Set the temperature to the material that's in the head, so 195°C (383°F) for PLA in this case, also select the
extruder that has the jam.