System Reference Code A9002000; System Reference Code A6005082; Failure To Display D1008065 And D1008066 Automatically After Calling The Function; Ipl Step C6004031 Takes Longer Than Expected - IBM E Server i Series Manual

Operations console, access for windows
Hide thumbs Also See for E Server i Series:
Table of Contents

Advertisement

System reference code A9002000

Possible reasons you received system reference code A90002000:
v If the system displays this SRC code, it usually means that a console was not
v The iSeries system value QAUTOCFG must be set to ON. OS/400 is unable to
v If you just migrated the console from one type to another and the new console

System reference code A6005082

Possible reasons you received system reference code A6005082:
v If the system displays this SRC code, it usually means that a console was found,
v If the console is reassigned and the server can locate the console, the SRC code
v The console type does not affect this SRC code.
Failure to display D1008065 and D1008066 automatically after
calling the function
When working with models that have a double row for the Function/Data display,
after calling the function, the control panel (and remote control panel) may not
automatically display the resulting SRC code. In these cases, you have to do a
function 11 in order to determine whether the function 65 or 66 completed
successfully. If the function did not complete successfully:
1. Using the control panel or the remote control panel, press the Up or Down
2. Press Enter.

IPL step C6004031 takes longer than expected

A change was made in V5R1 that allows the user to place a 2771 (9771) anywhere
within the processing unit (first tower) and have it found and used for Operations
Console. Depending on what other console-capable resources might be found plus
the time it takes to walk the bus, this activity has increased the amount of time
spent at this IPL step.

Troubleshoot remote control panel and virtual control panel problems

When setting up your initial connection you may encounter problems accessing
your control panels. Control panel problems that can occur:
If Word 17 value is:
1
Async card not
detected
2
No cables detected
3
Wrong cable detected
4
Port in use
found.
create the new console device if it is off.
fails to work in OS/400 you may need to use another workstation to manually
delete the controller and device description associated with the old console
device.
and then the server lost the console.
will go away. In this case, once the server is satisfied and can find the console,
the reference code will go away.
buttons until 11 is shown.
Failure
Word 18 means:
Card position
Card position
Card position
Chapter 6. Troubleshoot Operations Console connections
Word 19 means:
Cable ID
111