Technical Data - E+E Elektronik EE772 Series Manual

Flow meter for compressed air and gases
Hide thumbs Also See for EE772 Series:
Table of Contents

Advertisement

9.

TECHNICAL DATA

Measuring value
Flow
Measurand
Measuring range
standardized volumetric flow in air
standardized flow in air, CO2,
Accuracy
in air at 7bar (101.5 Psi) (abs) and 23°C (73°F)
Temperature coefficient
Pressure coefficient
Response time t
Sample rate
Temperature
Measuring range
Accuracy
at 20°C (68°F)
Outputs
Output signal and display ranges are freely scalable
Analogue output
Switching output
Pulse output
Bus output (optional)
Digital interface
Input
Optional pressure compensation
General
Supply voltage
Current consumption
Temperature range
Nominal pressure
Humidity
Medium
Connection
Electromagnetic compatibility
Material
Housing protection class
1) The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation). The accuracy was
culated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement).
2) The flow meter is calibrated at 7 bar (abs) 101.5 Psi. If the working pressure is different from 7 bar (101.5 Psi) you can compensate the error by setting the actual
pressure with the configuration software.
DN40
DN50
DN65
DN80
≤DN50
nitrogen
DN65
DN80
helium
≤DN50
DN65
DN80
1)
2)
90
voltage
current (3-wire) 0 - 20 mA and 4 - 20 mA
housing
probe
sensor head
ball valve
MultiController Aluminium
Volumetric flow at standard conditions acc. DIN 1343
P
= 1013.25 mbar
0
:
2.26...904 Nm
/h
3
(1 1/2")
:
3.50...1400 Nm
/h
3
(2")
:
5.97...1400 Nm
/h
3
(2 1/2")
:
9.04...1400 Nm
/h
3
(3")
:
0.5...200 Nm/s
(2")
:
0.5...117 Nm/s
(2 1/2")
:
0.5...77 Nm/s
(3")
:
0.5...120 Nm/s
(2")
:
0.5...117 Nm/s
(2 1/2")
:
0.5...77 Nm/s
(3")
± (1.5% of measuring value + 0.5% of full scale)
± (0.1% of measuring value/°C)
0.5% of measuring value / bar
< 1 sec.
0.5 sec.
-20...80 °C
(-4...176 °F)
± 0.7 °C
(1.26 °F)
0 - 10 V
potential-free max. 44 VDC, 500 mA switching capacity
Totalizer, pulse length: 0.02...2 sec.
MODBUS RTU or M-BUS (Meter-Bus)
USB (for configuration)
4 - 20 mA (2-wire; 15 V) for pressure sensor
18 - 30 V AC/DC
max. 200 mA (with display)
ambient temperature:
medium temperature:
storage temperature:
40 bar
(580 Psi)
no condensation
compressed air or none corrosive gases
cable gland M16x1.5 (optional connector M12x1 8pol.)
EN61326-1
Industrial Environment
metal (AlSi3Cu)
stainless steel
plastic (PBT)
brass
IP65 / Nema 4
20
; t
= 0 °C
(14.7 PSI)
(32°F)
0
1.33...531.8 SCFM
2.06...823.6 SCFM
3.51...823.6 SCFM
5.32...823.6 SCFM
100...39370 SFPM
100...23031 SFPM
100...15157 SFPM
100...23622 SFPM
100...23031 SFPM
100...15157 SFPM
max. 1 mA
R
<500 Ohm
L
-20...60 °C
(-4...140 °F)
-20...80 °C
(-4...176 °F)
-20...60 °C
(-4...140 °F)
EN61326-2-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ee772-aEe772-bEe772-c