Summary of Contents for E+E Elektronik EE08

  • Page 1 User Manual EE08 High-Precision Miniature Humidity and Temperature Probe BA_EE08 // v1.3 // Modification rights reserved...
  • Page 2 E+E Elektronik Ges.m.b.H. does not accept warranty and liability claims neither upon this publication nor in case of improper treatment of the described products. The document may contain technical inaccuracies and typographical errors. The content will be revised on a regular basis.
  • Page 3: Table Of Contents

    CONTENT General ..............................4 Explanation of Symbols ..........................4 Safety instructions ............................4 1.2.1 General Safety Instructions ..........................4 1.2.2 Intended Use ................................4 1.2.3 Mounting, Start-up and Operation ........................5 Environmental Aspects ..........................5 Scope of Supply ..........................5 Product Description ..........................5 General ................................5 Dimensions ..............................6 Electrical Connection .............................6 Installation ............................7 Maintenance ............................7...
  • Page 4: General

    Please refer to chapter 3 Product Description. The use of the EE08 in any other way than described in this manual bears a safety risk for people and the entire measurement installation and is therefore not allowed.
  • Page 5: Mounting, Start-Up And Operation

    Product Description General The EE08 is a probe for the highly accurate measurement of humidity (RH) and temperature (T) over wide RH and T ranges of 0...100 % RH and -40...80 °C (-40...176 °F). Typical application fields of the probe are Meteorology / weather stations ƒ...
  • Page 6: Dimensions

    For outdoor operation the use of an appropriate radiation shield is of paramount importance. The EE08 is compatible with rotational symmetric radiation shields which protect it against rain, snow and overheating caused by direct sunlight (available as accessory HA010502, suitable for type E8 and HA010506, suitable for type E11).
  • Page 7: Installation

    Maintenance The use in dirty, dusty, polluted environment might arise the need for cleaning the sensing head and replacing the filter cap. In such a case please see the Cleaning Instructions at www.epluse.com/EE08. Do not touch the humidity sensor! Calibration / Adjustment Definitions Calibration documents the accuracy of a measurement device.
  • Page 8: Accessories / Spare Parts

    EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement); nominal voltage V1 = 12 V DC, V2 = 24 V DC 2) For further support literature refer to www.epluse.com/ee08. User Manual for EE08 Humidity / Temperature Probe...
  • Page 9 HEADQUARTERS SUBSIDIARIES E+E Elektronik Ges.m.b.H. E+E Elektronik China E+E Elektronik Germany E+E Elektronik Korea Langwiesen 7 18F, Kaidi Financial Building, Schöne Aussicht 8 C Suite 2001, Heungdeok IT 4209 Engerwitzdorf No.1088 XiangYin Road 61348 Bad Homburg Valley Towerdong, 13, Austria 200433 Shanghai Tel.:...

This manual is also suitable for:

Ee08-m e8 seriesEe08-m e11 seriesEe08-m6 e8 series