Kessel Pumpfix F Standard Instructions For Assembly, Operation And Maintenance page 23

Backwater pumping station for wastewater with and without sewage
Table of Contents

Advertisement

Available languages

Available languages

Fig. 13 shows the Comfort variant
Locking lever
muff
Pump remo-
val lever
Fig. 14
Fig. 15
4. Service and maintenance
Pump remo-
val lever
Fig. 16
Probe test
4.4 Pump removal:
The pump can be removed individually.
To do this, turn both pump removal levers
through 180°. This makes them fold out-
wards to the side so that the pump can be
lifted out.
Lock both sides!
Locking lever
muff
4.5 Motor installation:
The levelled drive shaft of the motor must
be in a vertical position (state on deli-
very). Move the locking lever of the ope-
rating valve on the locking cover to the
"CLOSED" position, insert the drive
motor into the drive groove from above,
and screw in place using the four M5 x 12
screws (TX25) on the locking cover (Fig.
16).
4.6 Removing motor ground installation
In this case, the outlet cover must be dis-
mantled to remove the motor. To do this,
open the locking lever and take the out-
let muff out. Loosen levers ② and ③ and
remove the bypass muff, to do this tilt
pump connection muff ④ away or remo-
ve the pump if necessary. After removing
the two cover locking levers ⑤ the outlet
cover can be removed. Now the motor
can be screwed off.
Motor installation
23
❷ ❸

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pumpfix f comfort

Table of Contents