Kessel Pumpfix F Standard Instructions For Assembly, Operation And Maintenance page 21

Backwater pumping station for wastewater with and without sewage
Table of Contents

Advertisement

Available languages

Available languages

3.4 Installation in an exposed wastewa-
ter pipe
The version for free-standing set-up is deliver-
ed with a protective hood to prevent damage to
the components following commissioning. Fig.
7 shows the cable ducts – 1 or 2 (depending on
the variant).
Installation in water load
3.5
(Seal set art. no. 83023
Fig. 7
If the valve is to be installed in water load,
the flange serves as the necessary sealing
level for a white or black tub (see Figure).
For this purpose, seal sheeting is clamped
between the plastic counterflange and the
compression seal flange integrated on the
drain body, and screwed together using the
enclosed screws.
The sheeting used on site can be used as
seal sheeting. For installation in a waterpro-
of white tub, KESSEL also has matching
seal sheeting available made of natural rub-
ber NK/SBR, where the bore holes for the
screws have already been cut out (see Fig.
8).
If it is necessary to perforate the waterproof
concrete tub to connect feed pipes, cable
conduits etc., these holes must also be set
up waterproof. Maximum groundwater resi-
stance is 2 m.
nstallation example "black tub"
BWS
*
4
➀ KESSEL-Pumpfix® F, Staufix® FKA, Staufix® SWA, Controlfix
➁ Compression seal flange with seal set art. no. 83023
➂ Extension art. no. 83071
➃ Adapter DN 100 with compression seal flange made of stainless
steel art. no. 27198
3. Einbau
Installation with extension (order no.
83071).
Use of the extension allows the flange
height to be individually adjusted. The
attachment must be shortened to the re-
quired height if necessary.
Special features of Pumpfix
3.6
Comfort
Pumpfix F Komfort has an integrated drai-
ning function for surface water drainage.
Set-up
3.7
Connection of the draining function to the
feed cover is via the enclosed draining
connection. Insert the draining connection
into the prescribed opening and lock using
the one-handed quick-action closure.
Depending on installation depth (installati-
on depth of the upper cover section), the
draining connection must be shortened to
the respective length (see Fig. 9) or exten-
ded using HT-pipe DN 70 if recessed in-
stallation using extension (art. no. 83071) is
used.
Tiles
Fliesen
Screed
Estrich
Insulation
Dämmung
Concrete floor
Betonboden
Protective concrete
Schutzbeton
Sealing
Abdichtung
Underfloor
Unterbeton
2
3
1
®
Fig. 8
*
Fig 9
nstallation example "white tub"
BWS *
4
5
➄ Elastomer sealing sheet art. no. 27159
➅ Upper cover section with plastic cover plate
➆ Control unit
➇ Locking lever
21
Seal seat (83023)
• Counterflange • Sealing sheet
Pressdichtungsflansch
Pumpfix F Comfort
S
Tiles
Fliesen
Screed
Estrich
Insulation
Dämmung
Concrete floor
Betonboden
2
1
WU-Beton

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pumpfix f comfort

Table of Contents