HYOSUNG NH-1800CE Operator's Manual page 202

Table of Contents

Advertisement

NH-1800CE
Error Code
CS13 sensor detects a bill with hole during
4008F00
dispensing
CS31AB~CS13 Time out(Jam) during
4009A00
dispensing from 3rd cassette.
Trying to dispense bills from 3rd cassette but
4009D00
the 3rd cassette doesn't installed.
4009F00
3 cassette miss feed error
Something is detected on CS2 sensor after
400AC00
dispense operation
Communication error - Command Length
400BC00
doesn't match.
Bill pickup sensor(CS1, CS15) recognized has
400BE00
a hole and CS4 sensor detects it or CS4
snesor detects the gap too close
Cassette Jam during dispense operation
400C100
(1 CST Encoder Error).
Cassette Jam during dispense operation
400C200
(2 CST Encoder Error).
Cassette Jam during dispense operation
400C300
(3 CST Encoder Error).
Cassette Jam during dispense operation
400C400
(4 CST Encoder Error).
400C600
Error of CS 2, CS13 sensor during initialization
Description
6- 22
Trouble shooting
1.Remove a jammed note in 1 Cassette.
2.Replace 1 cassette box when multiple errors
occur.
1.Remove a jammed note in 2 Cassette.
2.Replace 2 cassette box when multiple errors
occur.
1.Remove a jammed note in 3 Cassette.
2.Replace 3 cassette box when multiple errors
occur.
1.Remove a jammed note in 4 Cassette.
2.Replace 4 cassette box when multiple errors
occur.
1.Remove a jammed note in CS13 sensor.
2.Replace CS13 sensor.
6. Appendix

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents