DICENTIS
14.4
Making a backup of the database
1.
2.
3.
4.
5.
Note: For a different location or name of the backup please use this command:
DcnmDatabaseConsole.exe -b [filename and location]. If the file already exists, the file will
be extended with the latest backup.
14.5
Restoring a database
1.
2.
3.
4.
5.
Refer to
–
–
14.6
Updating a database to the current version
1.
2.
3.
4.
5.
14.7
Creating a clean database
1.
2.
3.
4.
5.
Bosch Security Systems B.V.
Stop DICENTIS services using the DICENTIS Server Console.
Open a command prompt in Administrator mode.
Go to: C:\Program Files\Bosch\DICENTIS.
To create a backup, run DcnmDatabaseConsole.exe -b. The backup will be stored in C:
\Program Files\Microsoft SQL Server\MSSQL12.SQLDICENTIS2014\MSSQL\DATA
\DcnmBackup.
Restart the DICENTIS services using the DICENTIS Server Console.
Stop DICENTIS services using the DICENTIS Server Console.
Open a command prompt in Administrator mode.
Go to: C:\Program Files\Bosch\DICENTIS.
To restore the database, run DcnmDatabaseConsole.exe -r <filename and location of the
database>.
Note: Only *.bak files made by creating a backup can be restored.
Note: The restore command does not update the database to the current version. To
update it to the current version, please read Updating a database to the current version,
page 111 .
Note: If your backup is in the C:\Program Files\Microsoft SQL Server
\MSSQL10_50.SQLEXPRESS\MSSQL\DATA\DcnmBackup directory, an error notification
will appear because the SQL2014 has no access to this SQL2008 database. Please copy it
to C:\temp.
Restart the DICENTIS services using the DICENTIS Server Console.
Updating a database to the current version, page 111
Updating a database to the current version, page 111
Stop DICENTIS services using the DICENTIS Server Console.
Open a command prompt in Administrator mode.
Go to: C:\Program Files\Bosch\DICENTIS.
To update the database to the current version, run DcnmDatabaseConsole.exe.
Restart the DICENTIS services using the DICENTIS Server Console.
Stop DICENTIS services using the DICENTIS Server Console.
Open a command prompt in Administrator mode.
Go to: C:\Program Files\Bosch\DICENTIS.
Run DcnmDatabaseConsole.exe -n.
Restart the DICENTIS services using the DICENTIS Server Console.
Configuration manual
Hints and Tips | en 111
2021.06 | V3.7 |