Parameter
Heat Dist / Heat as time
Heat Speed
Use Weld Phase Mode
Job number
Wire Feed Speed
Arc Length Correction
Application manual - Fronius TPS 320i/400i/500i/600i with RI-FB inside/i interface
3HAC065012-001 Revision: C
Description
The blue refresh button is used to return to the Weld Phase tab.
The green check button is used to confirm any changes made.
The red cancel button is used to cancel any changes made and return
to the previous values.
Description
The distance during which the heat data is active at the start of
the weld.
If the parameter Heat as time is active the distance will be re-
placed by time (in seconds).
The welding speed during the heat phase at the start of the
weld phase.
Not selected – Select weld parameters during ignition phase
manually.
Selected – Use the parameters from the Weld tab. This is the
default mode.
The job (schedule) that should be selected within the welder.
The information displayed in the Job number is:
Job number, Job name.
This is the wire feed speed (Power). In this mode, the wire feed
speed can be adjusted in the range of +/- 20 % in 1% incre-
ments.
This parameter represents the arc length (Voltage).
In this mode, the Arc Length Correction can be adjusted in the
range of +/- 10 steps in 0.1 increments.
© Copyright 2004-2021 ABB. All rights reserved.
4 Weld editor interface
4.4 Weld editor in Job mode with correction
Continues on next page