Beretta MYNUTE X C Installer And User Manual page 30

Table of Contents

Advertisement

Available languages

Available languages

MYNUTE X
PARAMETERS
Lower Wobbe index (at 15°C-1013 mbar)
Net Calorific Value
Supply nominal pressure
Minimum supply pressure
25 C
Burner: diameter/length
Diaphragm: holes number - holes diameter
CH maximum gas capacity
DHW maximum gas capacity
CH minimum gas capacity
DHW minimum gas capacity
Number of fan rotations with slow ignition
Max number of CH fan rotations
Max number of DHW fan rotations
Min number of CH/DHW fan rotations
Max n° of CH fan rotations in C(10) configuration (Ø60-100 ● Ø80-125 ● Ø80)
Max n° of DHW fan rotations in C(10) configuration (Ø60-100 ● Ø80-125 ● Ø80)
Min n° of CH/DHW fan revolutions in C(10) configuration (Ø60-100 ● Ø80-125 ● Ø80)
30 C
Burner: diameter/length
Diaphragm: holes number - holes diameter
CH maximum gas capacity
DHW maximum gas capacity
CH minimum gas capacity
DHW minimum gas capacity
Number of fan rotations with slow ignition
Maximum number of CH fan rotations
Maximum number of DHW fan rotations
Minimum number of CH/DHW fan rotations
Max n° of CH fan rotations in C(10) configuration (Ø60-100 ● Ø80-125 ● Ø80)
Max n° of DHW fan rotations in C(10) configuration (Ø60-100)
Max n° of DHW fan rotations in C(10) configuration (Ø80-125 ● Ø80)
Min n° of CH/DHW fan revolutions in C(10) configuration (Ø60-100)
Min n° of CH/DHW fan revolutions in C(10) configuration (Ø80-125 ● Ø80)
35 C
Burner: diameter/length
Diaphragm: holes number - holes diameter
CH maximum gas capacity
DHW maximum gas capacity
CH minimum gas capacity
DHW minimum gas capacity
Number of fan rotations with slow ignition
Maximum number of CH fan rotations
Maximum number of DHW fan rotations
Minimum number of CH/DHW fan rotations
Max n° of CH fan rotations in C(10) configuration (Ø60-100 ● Ø80-125 ● Ø80)
Max n° of DHW fan rotations in C(10) configuration (Ø60-100)
Max n° of DHW fan rotations in C(10) configuration (Ø80-125 ● Ø80)
Min n° of CH/DHW fan revolutions in C(10) configuration (Ø60-100)
Min n° of CH/DHW fan revolutions in C(10) configuration (Ø80-125 ● Ø80)
40 C
Burner: diameter/length
Diaphragm: holes number - holes diameter
CH maximum gas capacity
DHW maximum gas capacity
CH minimum gas capacity
DHW minimum gas capacity
Number of fan rotations with slow ignition
Maximum number of CH fan rotations
Maximum number of DHW fan rotations
Minimum number of CH/DHW fan rotations
30
MYNUTE X C
UM
METHANE GAS
(G20)
MJ/m³S
45,67
MJ/m³S
34,02
mbar (mm H2O)
20 (203,9)
mbar (mm H2O)
10 (102,0)
mm
70/86
n° - mm
1 - 4,3
Sm³/h
2,12
kg/h
-
Sm³/h
2,64
kg/h
-
Sm³/h
0,38
kg/h
-
Sm³/h
0,38
kg/h
-
rpm
5.500
rpm
6.200
rpm
7.600
rpm
1.600
rpm
6.200
rpm
7.600
rpm
1.600
mm
70/125
n° - mm
1 - 5,2
Sm³/h
2,64
kg/h
-
Sm³/h
3,17
kg/h
-
Sm³/h
0,52
kg/h
-
Sm³/h
0,52
kg/h
-
rpm
5.500
rpm
5.800
rpm
6.900
rpm
1.700
rpm
5.800
rpm
7.250
rpm
6.900
rpm
1.750
rpm
1.700
mm
70/125
n° - mm
1 - 5,2
Sm³/h
3,17
kg/h
-
Sm³/h
3,66
kg/h
-
Sm³/h
0,52
kg/h
-
Sm³/h
0,52
kg/h
-
rpm
5.500
rpm
6.900
rpm
7.800
rpm
1.700
rpm
6.900
rpm
8.200
rpm
7.800
rpm
1.800
rpm
1.700
mm
70/125
n° - mm
1 - 5,2
Sm³/h
3,17
kg/h
-
Sm³/h
4,23
kg/h
-
Sm³/h
0,52
kg/h
-
Sm³/h
0,52
kg/h
-
rpm
5.500
rpm
6.900
rpm
9.100
rpm
1.700
LPG
(G31)
70,69
88
37 (377,3)
-
70/86
1 - 4,3
-
1,55
-
1,94
-
0,39
-
0,39
5.500
6.000
7.400
2.000
-
-
-
70/125
1 - 5,2
-
1,94
-
2,33
-
0,54
-
0,54
5.500
5.600
6.700
1.900
-
-
-
-
-
70/125
1 - 5,2
-
2,33
-
2,69
-
0,54
-
0,54
5.500
6.900
7.800
1.900
-
-
-
-
-
70/125
1 - 5,2
-
2,33
-
3,11
-
0,54
-
0,54
5.500
6.900
8.900
1.900

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mynute x 25 cMynute x 30 c

Table of Contents