Additive Components
Indicators on the operator control panel
Indicator
Meaning
ID
ID indicator (blue)
Lights up blue when the Application Unit has been selected by pressing the ID button. To deactivate,
press the button again.
The ID indicator can also be activated via the ServerView Operations Manager and the iRMC Web
GUI, and the status is reported to the ServerView Operations Manager and the iRMC.
Status indicator (green)
Does not light up when the Application Unit is switched off but is connected to the power supply
(power cable connected).
Lights up green during the power up delay and in normal system operation (S0).
Status indicator (power cable connected)( green)
on the right-hand side of the On/Off switch
Does not light up in the following cases:
The Application Unit is not connected to the power source
The Application Unit Unit is switched on and operating normally (S0)
Lights up green when one of the following cases occurs:
The Application Unit is switched off but connected to the power supply (power cable connected)
The Application Unit is switched on but is in the power up delay
i
After the Application Unit has been connected to the power source, it takes approximately
60 seconds until the Application Unit has entered standby mode.
HDD activity indicator (green)
Lights up green
when an internal hard disk drive or a solid state drive is being accessed.
16