22 - START UP CHECK LIST

Print name of start-up technician .................................................................................................. , date .............................................
Installer Name ........................................................................................................
Company ................................................................................................
Heater's serial number ...................................................................................... Model ............................................................
Street ................................................................................................. City ..........................................
State .............................................. Zip ......................................... Site altitude above see level .......................... ft
Is the installation manual present at site?
Are all requirements in terms of clearances from combustible materials be met?
Is the temperature and pressure relief valve properly sized and installed in accordance with the ANSI/ASME BPVC section IV?
Is the heater properly grounded?
Are all requirements in terms of gas supply be met?
LWCO (or any safety devices downstream the appliance) intervention stops all burners sending unit in Loc 29?
Is a filter properly sized and installed in the water inlet (water return) pipe?
Water hardness ......................... ppm
Water flow readed on parameter 1062 ........................ GPM multiply by the quantity of burners .......................... GPM (total water flow on appliance).
Is this last matching the requirements in terms of prevention of scaling (see manual)?
Static/Dynamic Gas Inlet Pressure = .................... / .................... W.C.
Vent and combustion air:
Are all requirements in terms of ventilation of the equipment room be met?
Material used in venting system:
Venting pipe: diameter .................... inch , length ....................... equivalent feet.
Material used in air inlet pipe (if any):
Air inlet pipe: diameter .................... inch , length ....................... equivalent feet.
Are any draw venting present (such as extractors, barometric dampers, blast dampers or draft inducers)?
Are all requirements in terms of flue exhaust and air intake be met?
Are all requirments in terms of positioning of the flue exhaust and air intake terminals be met?
Is the flue exhaust pipe properly glued and sealed tight to the heater exhaust adapter?
Room Temp.
(1)
...................... °F
CO
(%)
2
Burner 1 (Master)
Burner 2
Burner 3
Burner 4
(1) compare Installation Manual for range/limits
(4) less than 150 ppm (natural gas) or 250 ppm (LP gas)
If you answered "No" to any question describe the reason:
.....................................................................................................................................................................................................................................................................
...................................................................................................................................................................................................................................................................
Information must be sent to info@cosmogas.com in order to ensure warranty consideration.
IDENTIFICATION DATA
Yes
No
GENERAL INSTALLATION
Yes
No
Yes
Combustion air from room
Stainless steel
PVC
Stainless steel
COMBUSTION ANALISATION
HIGH FIRE
(1)
(4)
O
(%)
CO (0% O
)
2
2
(2) compare local codes for limis
Phone number .................................................................
DOCUMENTATION
Are all manual information well understood by the heater owner?
Yes
Is a general main electrical switch installed near the heater?
No
Type of gas:
Yes
No
VENTING
Direct vent
Yes
No
CPVC
Polypropylene
PVC
CPVC
Polypropylene
Yes
No
(2)
(3)
NO
(ppm)
Tf (°F)
X
(3) flue gas temperature must be less than return temperature + 45°F.
No
Natural gas
LP gas
Yes
Yes
No
Yes
No
Yes
No
Yes
No
LOW FIRE
(1)
(1)
CO
(%)
O
(%)
CO (0% O
2
2
Yes
No
Yes
No
Yes
No
No
(4)
(2)
)
NO
(ppm)
2
X