5 - INSTALLATION - Location

5.1 - Choosing the
installation location
WARNING!!!
Do not store
any flammable materials or
liquids in the immediate vicinity
of the appliance. A fire or
explosion can result, causing
severe personal injury, death, or
substantial property damage.
WARNING!!!
Do not install
the appliance on carpeting.
Fire can result, causing severe
personal injury, death, or
substantial property damage.
WARNING!!!
Provisions for
combustion air and ventilation
of the appliance room are
always required, regardless
whether the combustion air is
taken from the outside (Direct
Vent, sealed combustion)
or inside (room air for
combustion). Failure to comply
with this provision could result
in excessive levels of carbon
monoxide or a fire, which can
result in severe personal injury
or death!
WARNING!!!
Insufficient
ventilation of the appliance
room can lead to high air
temperatures. Failure to comply
with this provision could result
in excessive levels of carbon
monoxide or a fire, which can
result in severe personal injury
or death!
WARNING!!!
Make
sure that intake and exhaust
openings are sufficiently sized
and no reduction or closure of
openings takes place. When the
problem is not resolved, do not
operate the appliance. Please
note these restrictions and its
dangers to the operator of the
appliance. Failure to comply
with this provisions could result
in severe personal injury, death,
or substantial property damage.
WARNING!!!
LIQUEFIED
PETROLEUM (L.P.) PROPANE
GAS-FIRED Appliance
LOCATION REQUIRES SPECIAL
ATTENTION: 1994 UNIFORM
MECHANICAL CODE, Section
304.6: "LPG Appliances.
Liquefied petroleum gas-burning
appliances shall not be installed
in a pit, basement or similar
location where heavier-than-air-
gas might collect. Appliances
so fueled shall not be installed
in an abovegrade under-floor
space or basement unless such
location is provided with an
approved means for removal
of unburned gas." Failure to
comply with this provision could
result in and explosion that can
cause severe personal injury,
death, or substantial property
damage.
CAUTION!!!
This appliance is
not designed for direct outdoor
installation. If installed outside of
the structure, it must be sheltered
so it is protected from rain, wind,
sun and frost. NEVER place this
appliance in a location that would
subject it to temperatures at or near
freezing or temperature that exceed
100°F (38°C). Failure to properly
locate this appliance can result in
premature failure.
CAUTION!!!
This appliance must
be installed in a location so
that any water leaking from the
appliance or piping connections
or relief valve openings will
not cause damage to the area
surrounding the unit or any
lower floors in the structure.
CAUTION!!!
When installed in a
room with thin floor, resonating
noise may occur. Install noise
reducing parts if required.
CAUTION!!!
Do not allow too
much dust to collect on the
appliance.
31
Maintain minimum specified clearances
for adequate operation. All installations
must allow sufficient space for servicing
the vent connections, water pipe
connections, piping and other auxiliary
equipment, as well as the appliance.
The clearance labels on each appliance
note the same service and combustible
clearance requirements as shown on
Section 5.4 and 5.5.
Multiple appliances may be installed in
a modular appliance installation.
Consult the venting section of this
manual for specific installation
instructions for the appropriate type of
venting system that you will be using.
Direct vent and vent/air venting systems
require installation with Category IV
flue pipe, sealed air inlet pipe, and
air inlet caps, which must meet the
manufacturer's specifications.