13 - INSTALLATION - Gas supply
Figure 13-8 - Label for LP
gas appliance
Figure 13-9 - Label for
Natural gas appliance
13.7 - Convert a
appliance model
399, 500, 750 or
1000 from Natural
Gas to Propane gas
or viceversa
Appliances model 399, 500, 750 or
1000 are multiburner appliances. This
means that the gas conversion must
be performed on each burner present
inside the unit.
WARNING!!!
The gas
conversion shall be performed
by a qualified service agency
in accordance with this
instructions and all applicable
codes and requirements of the
authority having jurisdiction.
The information in these
instructions must be followed
to minimize the risk of fire
or explosion or to prevent
property damage, personal
injury or death. The qualified
service agency is responsible
for the proper conversion
of the appliance. The
installation is not proper and
complete until the operation
of the converted appliance is
checked as specified in this
instructions.
WARNING!!!
The
conversion shall be carried
out in accordance with
the requirements of the
provincial authorities having
jurisdition and in accordance
with the requirements of the
CAN-B149.1 and CAN1-B149.2
installation code.
87
Contents:
The conversion kit (supplied with
the appliance) is composed of
the following elements, which are
necessary for the gas change:
- a label rating stating the new gas
setting;
- an instruction sheet;
- an orifice per each burner present
on the unit.
Installing:
in order to make the gas change
please follow the instructions below:
1.- Operate to convert the "Burner
1 (Master)". See Figures 3-7 and
3-10 to identify "Burner 1 (Master)";
2.- Operating on "Burner 1 (Master)"
following exactly Section 13.6 from
point 1. to 16.;
After converting "Burner 1 (Master)"
you have to operate on "Burner 2"
(See Figure 3-7 and 3-10) and:
3.- Follow exactly Section 13.6 from
point 1. to 16.;
After converting "Burner 2" you have
to operate on "Burner 3", if present
(See Figure 3-7 and 3-10), and:
4.- Follow exactly Section 13.6 from
point 1. to 16.;
After converting "Burner 3" you have
to operate on "Burner 4", if present,
(See Figure 3-7 and 3-10) and:
5.- Follow exactly Section 13.6 from
point 1. to 16.;
After converting all burners:
6.- Check the inlet gas pressure of the
unit, following Section 14.7;
7.- Check the capacity input of the unit
following Section 14.9;
8.- Attach to the front of the appliance
the appropriate conversion label,
found in the conversion kit stating
the new type of gas adjustment of
the appliance as follow:
a - Apply the label in Figure 13-8
if the appliance has been
converted to LP GAS;
b - Apply the label in Figure 13-9
if the appliance has been
converted to NATURAL GAS.