9 - INSTALLATION - Electrical connections
9.1.1 - Connecting the
power supply cable
Provide and install a fused disconnect or
service switch (15 amp recommended)
as required by the code. To connect the
electrical power supply cable, follow the
steps below while referring to Figures
9-1, 9-3 or 9-4:
1.- Remove the appliance casing
following the instructions given in
Section 16.2 and open the junction
box cover;
2.- Install the power supply wires, "B"
and "C" to terminals "101" and "102".
connect the ground wire to the ground
terminal;
3.- Connect the 120 volt hot wire to
terminal "101";
4.- Connect the 120 volt neutral wire to
terminal "102".
NOTICE! If the 120 volt power wires
are inverted, the appliance will block,
displaying error code Err 65.
Figure 9-1 - Junction box
52
A = Cable conduit
B = Line (Hot) cable
C = Neutral cable
D = Ground cable