Correct Positioning Of The Ignition And Flame Detection Electrodes; Clean The Air Filter - RBI Infinite Energy2 IW199 Installation And Operation Instructions Manual

Table of Contents

Advertisement

16 - MAINTENANCE
A = Left ignition electrode
B = Right ignition electrode
C = Flame detection electrode
Figure 16-8 - Positioning electrodes on burner
(Use a hand caliper to verify the distances)
A
020010.01.018
B
Figure 16-9
- Remove the air filter "B"
110
16.4 - Correct
positioning of
the ignition and
flame detection
electrodes
For the appliance to work properly
the electrodes must be positioned as
shown in Figure 16-8:
NOTICE! To insure correct functioning
of appliance the distances listed
above shall be verified very carefully
also using a hand caliper.
16.5 - Clean the air
filter
For the appliance to work properly, the
air filter must be clean. A dirty air filter
can cause a power input reduction
of the unit, resulting in system
malfunctions. Operate as follows in
order to clean the air filter:
1.- Follow the steps in Section 16.2
to gain access to the internal
components;
2.- Pull down with a rotation the air
filter "B" as per Figure 16-9;
3.- Pull back the air filter and remove
it from the unit;
4.- With compressed air, clean the
surface of the air filter;
5.- Reassemble the air filter.