Technical Data - RBI Infinite Energy2 IW199 Installation And Operation Instructions Manual

Table of Contents

Advertisement

17 - TECHNICAL DATA

Appliance MODEL
Category of discharge chimney
Maximum heat input
Minimum heat input
Turndown ratio
Number of burners
Gas flow rate (Natural gas)
Gas flow rate (LP gas)
Min / Max gas pressure (Nat. and LP)
Min / Max water temperature
Min / Max water pressure
Minimum water flow with motorized valves
Minimum water flow without motorized valves
Content of water
Supply voltage / Frequence
Absorbed electric power
Air intake / Flue gas pipes diameter
Max. length venting system
CO (Carbon monoxide) with natural gas
CO (Carbon monoxide) with LP gas
NOx (0% O2 with natural gas)
CO2 (Carbon dioxide) for Natural gas at high fire
CO2 (Carbon dioxide) for Natural gas at low fire
CO2 (Carbon dioxide) for LP gas at high fire
CO2 (Carbon dioxide) for LP gas at low fire
O2 (Oxygen) for Natural gas at high fire
O2 (Oxygen) for Natural gas at low fire
O2 (Oxygen) for LP gas at high fire
O2 (Oxygen) for LP gas at low fire
Ionisation current
Maximum flue gas temperature
Max. negative pressure allowed in the fumes
exhaust/intake system
Maximum water condensate flow
Average acidity of condensation
Appliance weight (empty of water)
Recovery Rating (100°F rise)
DHW delivery (75°F rise)
Btu/hr
Btu/hr
ft3/hr
ft3/hr
In.W.C.
°F
PSI
GPM
GPM
gal
W
inch
ft
ppm
ppm
ppm
%
%
%
%
%
%
%
%
uA (Micro Amps)
°F
InWC
GPM
PH
lb
Gal/hr
GPM
124
199
II and IV
199,500
50,000
4:1
1
199.5
80
3 / 13
68 / 180
8 / 160
11
11
1.7
120Vac 60Hz
110
3
120
<150
<250
<30
8.4 to 8.7
8.4 to 8.7
9.5 to 10
10.5 to 11.5
5.9 to 5.4
5.9 to 5.4
6.4 to 5.6
4.8 to 3.4
4 to 7
203
0.2
0.032
4
211
227
5

Hide quick links: