1. DEFINITION OF THE ATEQ F670
The ATEQ F670 is a compact air/air
leak detector used to test the air-
tightness of parts. The method used
is based on the measurement of a
small variation or drop in differential
pressure between the test and
reference parts, when both are filled
to an identical pressure.
2. MEASUREMENT CHARACTERISTICS
2.1. P
RESSURE DROP MEASUREMENT
RANGE
0 – 500 Pa
2.2. T
EST PRESSURE MEASUREMENT
RANGE
F.S. = 200 mbar
0.2 < F.S. ≤ 5 bar
5 < F.S. ≤ 10 bar
F.S. = Full scale.
MR-36300C-U
PREAMBULE
TEST
PART
ACCURACY
+/- (2,5% of the pressure + 1 Pa)
ACCURACY
+/- (1,5% of the pressure+ 0,2 hPa)
+/- (1,5% of the pressure + 7.5 hPa)
+/- (1,5% of the pressure + 15 hPa)
DIFFERENTIAL
SENSOR
TEST
PRESSURE
RESOLUTION
Maximum
RESOLUTION
Quick start manual ATEQ F670 Page 2/25
Quick start - F670
REFERENCE
PART
PIEZO
SENSOR
0,1 Pa
Maximum
0,1 % F.S.
0,1 % F.S.
0,1 % F.S.