ATEQ F600 Quick Start Manual
Hide thumbs Also See for F600:

Advertisement

ATEQ F600
Quick Start Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ATEQ F600

  • Page 1 ATEQ F600 Quick Start Guide...
  • Page 2: Table Of Contents

    2 / 02 Safety advisory / Warranty Good practices and safety instructions Air quality requirements Preamble ATEQ F600, a universal leak tester Leak test Principle of a cycle Your ATEQ F600 Front panel Connectors on the back panel (with all options)
  • Page 3 ATEQ Manufacturer Plants - Measurement Solution, Global Leader. 3 / 38 ATEQ info@ateq.com T.: +33 1 30 80 1020 15, rue des Dames, Z.I. ateq.com F.: +33 1 30 54 1100 78340 LES CLAYES-SOUS-BOIS FRANCE ATEQ K.K. info@ateq.co.jp T.: +81 566-84-4670 3 –...
  • Page 4: Safety Advisory / Warranty

    Recommendations for the test environment Keep the test area as clean as possible. Recommendations for operators ATEQ recommends that the operators who use the devices have training and a level of qualification that correspond to the job to perform. General recommendations —...
  • Page 5: Air Quality Requirements

    For this purpose we strongly recommend that a suitable airtight filter is installed between the part under test and the instrument. ATEQ recommends the following characteristics for the air supplied into the device. Air characteristics ISO standard 8573 class Grain size and concentration 0.1 μm and 0.1 mg/m3...
  • Page 6: Preamble

    Preamble 6 / 38 ATEQ F600, A UNIVERSAL LEAK TESTER ATEQ F600 is a leak detector that tests the airtightness of parts. ATEQ F600 can memorise 128 different test programs. LEAK TEST Leak test (Desensitized) The test pressure is applied to the input of the test part 3.
  • Page 7: Principle Of A Cycle

    PRINCIPLE OF A CYCLE The measurement cycle is made of 4 main phases: fill, stabilization, test, dumping. 7 / 38 Pressure Time Cycle start Cycle end Waiting phase Fill phase Stabilization phase Test Dumping QSG_F600.415.00_EN_01 / 2019-04-16...
  • Page 8: Your Ateq F600

    Your ATEQ F600 8 / 38 FRONT PANEL The user interface is located on the front panel. Display Cycle keys Navigation keys USB connectors Quick connector Mechanical Regulator For more information, refer to User interface QSG_F600.415.00_EN_01 / 2019-04-16...
  • Page 9: Connectors On The Back Panel (With All Options)

    CONNECTORS ON THE BACK PANEL (WITH ALL OPTIONS) 9 / 38 QSG_F600.415.00_EN_01 / 2019-04-16...
  • Page 10 10 / 38 Name Description Analog outputs - pressure and leak (option) Fieldbus connector (option) Program selection extension connector (option) Printer RS232 connector / Modbus (option) or Profibus (option) Exhaust output Input connector to the air filter (regulator air supply) Pilot pressure input Pneumatic output for B automatic connector option Pneumatic output for A automatic connector option...
  • Page 11: Power Supply Connectors

    POWER SUPPLY CONNECTORS The device can be connected to an external power supply (24 V DC - 2 A) or provided with an internal power supply (100 / 240 V AC) (option). 11 / 38 External supply 24 V DC connector (J7) The device can be connected to a 24 V DC - 2 A power supply through a M12 4 pins type connector.
  • Page 12 Internal supply only 100 / 240 V AC connector (J7) (option) 12 / 38 The device can be connected to a 100 / 240 V AC power supply (option). This connector has a ON/OFF button. It is mandatory to connect the device to the ground with a good link to the ground, to protect against electric hazard or electrocution.
  • Page 13: Digital Links

    DIGITAL LINKS PC USB connectors (on front face) 13 / 38 USB connectors can be used for connecting miscellaneous compatible USB devices. The USB connectors are located under the rubber cover 1 (see figure). Rubber cover USB connector to PC USB connector to USB key Do not connect two USB devices at the same time.
  • Page 14 VP (supply) Not used Data line B Not used Devicenet connectors (J5) (J6) (option) M12 type connector - 5 pins male connector (J5) (Devicenet input) For connection to others ATEQ devices. Pin number Signal Drain CAN_H CAN_L M12 type connector - 5 pins female connector (J6) (Devicenet output) For connection to others ATEQ devices.
  • Page 15 Profinet connectors (J5 + J6) (option) M12 D coded type connector - 4 pins female connector (J5 + J6) 15 / 38 Pin number Signal Ethernet Tx + (Transmit Data +) Ethernet Rx + (Receive Data +) Ethernet Tx - (Transmit Data -) Ethernet Rx - (Receive Data -) Ethernet connector (J5 + J6) (option) Standard connection Ethernet TCP / IP protocol.
  • Page 16: Analog Outputs (Option)

    ANALOG OUTPUTS (OPTION) M12 type connector - 8 pins female connector (J1) 16 / 38 Pin number Signal Ground Pressure 0 - 10 V DC Pressure Ground Pressure (Diff) 0 - 10 V DC Pressure (Diff) Signal contact event Ground contact event Other options Other options DIGITAL INPUTS/OUTPUTS...
  • Page 17 Pin number Inputs / outputs Description Input 1 RESET 17 / 38 + 24 V DC Common Input 2 START + 24 V DC Common Input 3 Program selection Input 4 Program selection Input 5 Program selection Input 6 Program selection Input 7 Program selection (programmable input) Output...
  • Page 18 Program selection (J11 and J10) The connectors J11 and J10 (option) enable you to select a program from digital inputs. Combinations of connector pins to activate for program selection 18 / 38 Program number Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 1...
  • Page 19 Valve codes and auxiliary outputs board connector (J9) (option) Characteristics 19 / 38 — Outputs: 24 V DC - 100 mA max per output. • — Inputs: Activation: + 24 V DC. • Pin number Inputs / outputs Description + 24 V DC Common (outputs 1, 2,3) Output 1 Open collector...
  • Page 20: Pneumatic Connectors

    20 / 38 Pneumatic supply The pneumatic supply has to meet specific requirements recommended by ATEQ. Refer to Good practices and safety instructions section. A specific filter may be necessary. The air is supplied via the filter located on the back panel of the device.
  • Page 21 Quick connector (on front face) (option) Use this function to check the calibration. 21 / 38 As this connector is part of the measurement circuit, all its connections must be air tight. Test outputs The output enables parts to be connected (test) Test connector Exhaust output Metallic fitting available for test ...
  • Page 22 Air supply input for options Instant fitting: 6 mm diameter — Vacuum input for vacuum range 22 / 38 QSG_F600.415.00_EN_01 / 2019-04-16...
  • Page 23: Pneumatics Configuration

    PNEUMATICS CONFIGURATION 23 / 38 Direct mode - Vacuum Connections Connection Option / description Vacuum to 1 Connection to the vacuum (option) 3 to 2 Connection of the test output to the part under test Air supply to 4 Connection of the air supply (0.6 MPa (87 PSI)) for pneumatic output option only (see Pneumatic output 0.6 MPa (87 PSI) (option)) QSG_F600.415.00_EN_01 / 2019-04-16...
  • Page 24 Direct mode Maximum pressure: 1 MPa (145 PSI) 24 / 38 Connections Connection Option / description Regulator air supply to 1 Connection of the regulator air supply to the filter input (1.2  MPa (174 PSI)) Air supply to 2 Connection of the air supply (0.6 MPa (87 PSI)) for pneumatic output option only (see Pneumatic output 0.6 MPa (87 PSI) (option)) 4 to 3...
  • Page 25: User Interface

    User interface 25 / 38 OVERVIEW The user interface comprises a display and user keys located on the front panel. Display Cycle keys Navigation keys KEYS Cycle keys The cycle keys are used to start and to stop a measurement cycle. Name Function Start...
  • Page 26: Display

    Navigation keys The navigation keys are used to select menus/options and change parameter values. 26 / 38 Name Function Up key Scrolls up or increases numerical values. Down key Scrolls down or decreases numerical values. Returns to the MAIN MENU screen or opens menus and options, validates parameters.
  • Page 27 The Measurement cycle screen The Measurement cycle screen displays the different values of the current test (or last one). Test pressure measurement 27 / 38 Test result or step phase Test reject value TEST 0.742 Vertical line test result 13.00 Remaining time of the current phase or ready status 1.3 s...
  • Page 28: Starting Up

    Starting up 28 / 38 POWER UP 1. Make sure that all the necessary connections are in place. Electrical: such as power supply, inputs/outputs Pneumatic: including line pressure supply 2. Power up your device. When power-up is completed, the Program screen is Pr 001 displayed with last program used on screen.
  • Page 29: Modifying A Parameter

    CONFIGURING THE ASSOCIATED MEASUREMENTS 3. Select a measurement type and press 29 / 38 The parameters of the selected measurement type are PARAM / Pr 001 TYPE : LEAK TEST displayed. COUPL. A 0.0 s 2.0 s 4. Define the measurement cycle parameters. FILL TIME STAB TIME 2.0 s...
  • Page 30: Selecting A Program

    SELECTING A PROGRAM 30 / 38 If necessary, you can select another program. 1. Press up/down Pr 001 LEAK TEST (D) STARTING AND STOPPING CURRENT CYCLE Use the front panel keys to start/stop a measurement cycle. With the desired program displayed on the Program screen: STARTING A MEASUREMENT CYCLE 1.
  • Page 31: User Adjustments

    User adjustments 31 / 38 OPTIONS OF THE MENUS SPE CYCLE menu Use this menu to carry out specific procedures necessary to ensure the proper operation of specific measurement cycles. SPECIAL CYCLE MENU none Inf Fill Piezo auto zero Label Special cycle Description of the cycle none...
  • Page 32 PARAMETERS menu Use this menu to configure the measurement cycle associated to each test program. 32 / 38 PARAM / Pr 001 TYPE : LEAK TEST COUPL. A 0.0 s FILL TIME 2.0 s STAB TIME 2.0 s TEST TIME 2.0 s DUMP TIME 1.0 s...
  • Page 33 Additional functions 33 / 38 Label Function Description 24V OUTPUTS Auxiliaries output 24 V Available outputs for external automatism ABSOLUTE Absolute Display the absolute value of the results ATF time Absorb the important leak variations at the defined time ATR0 / ATR1 / ATR 0 - 3 Specific filters on leak measurement ATR2 / ATR3...
  • Page 34  CONFIGURATION menu Use this menu to configure your ATEQ device. 34 / 38 MAIN /CONFIGURATION LANGUAGE PNEUMATIC AUTOMATISM SECURITY MISCELLANEOUS Label Function Description LANGUAGE Language Selection of the language displayed on the screen PNEUMATIC Pneumatics Configuration of the pneumatics functions of the device > ELEC.
  • Page 35  SERVICE menu Use this menu to do the maintenance of your device (status check, internal tests...). 35 / 38 MAIN /SERVICE CAN STATUS I/O STATE VALVE COUNTER DEVICE INFOS SERVICE CYCLES RESET PARA Label Function Description CAN STATUS Internal network state State of the internal network of the device I/O STATE Inputs/outputs state...
  • Page 36  USB menu This section describes save and restore parameters on an external USB device. 36 / 38 MAIN /USB Save parameters Restore parameters Label Description Save parameters Save parameters on an external USB memory device for restoring later Restore parameters Restore parameters from an external USB memory device QSG_F600.415.00_EN_01 / 2019-04-16...
  • Page 37: Specifications

    Specifications 37 / 38 CHARACTERISTICS Technical characteristics of the device. Main characteristics Characteristics Values Case dimensions: Height x Width x Depth 150 x 250 x 270 mm (5.91 x 9.84 x 10.63") Overall dimensions 150 x 250 x 360 mm (5.91 x 9.84 x 14.17") Format Half 19-inch rack Mass...
  • Page 38 38 / 38 QSG_F600.415.00_EN_01 / 2019-04-16...

Table of Contents