Data Logger Programming - Campbell CS240 Product Manual

Pt-1000 class a, back-of-module temperature sensors
Hide thumbs Also See for CS240:
Table of Contents

Advertisement

(p. 11)). Using connectors between the sensor head and the station or data logger cable allows in-
field sensor head replacement without disconnecting the cable from the data logger.
The following table provides sensor wiring and cable pin-out. Detailed information about the
cables are provided in the
Configuration Utility and the MeteoPV User Interface.
Table 7-3: Wire Colour, Station Connection, and Function for the CS240DM
1
Standard cable
wire colour
Blue
White/blue stripe
Brown
White/brown stripe
Green
--
1
Cable has an 8-pin M12 connector.

7.2 Data logger programming

Short Cut is the best source for up-to-date data logger programming code. If your data
acquisition requirements are simple, you can probably create and maintain a data logger
program exclusively with Short Cut. If your data acquisition needs are more complex, the files that
Short Cut creates are a great source for programming code to start a new program or add to an
existing custom program.
NOTE:
Short Cut cannot edit programs after they are imported and edited in CRBasic Editor.
A Short Cut tutorial is available in
CRBasic Editor to create or add to a customized program, follow the procedure in
Short Cut code into CRBasic Editor
provided in the following section. Complete program examples for select CRBasic data loggers
can be found in
Example programs
If applicable, please read
to programming your data logger.
CS240 and CS240DM PT-1000 Class A, Back-of-Module Temperature
Specifications
(p. 6). Sensor wiring is also available in the Device
3-twisted pair cable
Pin-out
wire colour
3
Green
2
White
4
Red
1
Black
5
Yellow
N/A
Clear
QuickStart
(p. 22). Programming basics for CRBasic data loggers are
(p. 23)
Electrical noisy environments
Station (data
1
logger)
terminal
A– (C odd)
B+ (C even)
12V
G (⏚)
G (⏚)
(p. 2). If you wish to import Short Cut code into
(p. 16) and
Function
RS-485 A/A [–]
RS-485 B/B [+]
5 to 30 VDC
G
Ground (power)
Modbus common
Shield
Importing
Long cable lengths
(p. 16) prior
Sensors     11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs240dm

Table of Contents