Campbell CS240 Product Manual page 13

Pt-1000 class a, back-of-module temperature sensors
Hide thumbs Also See for CS240:
Table of Contents

Advertisement

Weight:
CS240DM
analogue-to-digital module (DM): 
A/D measurement
uncertainty:
Supply voltage:
Power consumption:
Surge protection:
Environmental protection:
IP rating:
CS240DM communications:
Protocol:
Format:
Baud rate:
Modbus ID:
Approvals:
Compliance:
Industrial standards:
Cable
Jacket material:
Wire size and type:
Nominal wire diameter:
CS240 and CS240DM PT-1000 Class A, Back-of-Module Temperature
90.7 g (0.2 lb) with 3.2 m (10.5 ft) cable
24-bit ADC
±0.015 °C
5 to 30 VDC
15 mA
1200 V isolation
Rugged overmoulding
IP68 rating (self certified); 1 m submersion for 90 min
Modbus RTU (over RS-485)
8 data bits, 1 stop bit, even parity as default (user
configurable)
19200 bps as default (user-configurable)
Last two digits of serial number as default (user-
configurable)
UL AWM 2586 1000V 105 °C; CSA AWM 600V 105 °C FT1
Conforms with Electromagnetic Compatibility Directive
(EMC)
Conforms with the Restriction of Hazardous Substances
Directive (RoHS2)
View compliance documents at:
www.campbellsci.eu/cs240
www.campbellsci.eu/cs240dm
Compliant with IEC 60751, DIN EN 60751,
Industrial Design (IEC Class 4) (according to IEC 751)
Black semi-gloss PVC, UL VW-1 sunlight resistant for
outdoor use
24 AWG (7/32) tinned copper
0.61 mm (0.024 in)
or