Sign In
Upload
Manuals
Brands
Campbell Manuals
Control Unit
SDM-SIO1A
Campbell SDM-SIO1A Manuals
Manuals and User Guides for Campbell SDM-SIO1A. We have
3
Campbell SDM-SIO1A manuals available for free PDF download: Instruction Manual
Campbell SDM-SIO1A Instruction Manual (44 pages)
Brand:
Campbell
| Category:
I/O Systems
| Size: 4.28 MB
Table of Contents
Table of Contents
9
Introduction
11
SDM-SIO1A Serial Input/Output Module
11
Precautions
12
Initial Inspection
13
Overview
13
Specifications
14
Supported Data Rates and Protocols
14
Electrical Parameters
15
Current Consumption
15
Voltage Specifications
16
Compliance
16
Temperature and Humidity Ranges
16
Dimensions and Weight
16
Sdm-Sio1A
16
Sdm-Sio4A
17
Datalogger Compatibility
17
Installation
17
Mounting
18
Connection and Wiring
19
SDM Address Settings
19
SDM-SIO1A Terminal Labels and Functions
20
SDM-SIO1A Functional Description of the Connections
20
Wiring Examples for Connecting the SDM-SIO1A
21
RS-485/RS-422 Full-Duplex, One-To-One Connection Example
22
RS-485 Full-Duplex, Multi-Drop Example
22
RS-485 Half-Duplex Wiring Example
23
RS-232 Wiring Example with Handshaking
24
RS-232 Basic 3-Wire Example
24
Connecting a 9-Way Socket to the SDM-SIO1A for RS-232 Devices
25
Programming
26
Crbasic Instructions
26
Serialopen()
26
Communications Port Parameters RS-232
27
Communications Port Parameters RS-485 Full Duplex
27
Communications Port Parameters RS-485 Half Duplex
28
Communications Port Parameters RS-232 Receive-Only Mode
28
Serialclose()
29
Serialin()
29
Serialout()
29
Serialinblock
30
Serialoutblock
30
Serialinchk
30
Serialinrecord
30
Serialflush
30
Example Datalogger Programs
30
Example Using RS-232 Mode
31
RS-232 Mode Example
31
Example Using RS-485 Mode
32
RS-485 Mode Example
32
Operation
33
Configuring Handshaking and Receive-Only Modes
33
Using RTS/CTS and Automatic Handshaking
33
RS-485 Half-Duplex Mode
33
Using the RS-232 Link in Receive-Only Mode
34
Power Conservation
34
Schematic
34
Troubleshooting and Maintenance
35
Troubleshooting
35
RS-485 Internal Circuit Diagram
35
Maintenance
36
Upgrading the Operating System
37
Operating System Signature Errors
37
Checking the Operating System Version and Signature
38
The Input Pin (Cts/Pin 11
39
Using the Handshaking Lines for General Input/Output
40
The Output Pin (Rts/Pin 8
40
Matching SDM-SIO1A Connections to an
41
Sdm-Sio1
41
Advertisement
Campbell SDM-SIO1A Instruction Manual (42 pages)
Serial Input/Output Module
Brand:
Campbell
| Category:
Control Unit
| Size: 1.69 MB
Table of Contents
Table of Contents
7
1 Introduction
9
2 Precautions
9
SDM-SIO1A Serial Input/Output Module
9
3 Initial Inspection
10
4 Overview
10
5 Specifications
11
Supported Data Rates and Protocols
11
Electrical Parameters
12
SDM-SIO1A Current Consumption
12
SDM-SIO1A Voltage Specifications
13
Compliance
13
Temperature and Humidity Ranges
13
Dimensions and Weight
13
Datalogger Compatibility
14
6 Installation
14
Mounting
15
Connection and Wiring
16
SDM Address Settings
16
SDM-SIO1A Terminal Labels and Functions
17
SDM-SIO1A Functional Description of the Connections
17
Wiring Examples for Connecting the SDM-SIO1A
18
RS-485/RS-422 Full-Duplex, One-To-One Connection Example
18
RS-485 Full-Duplex, Multi-Drop Example
19
RS-485 Half-Duplex Wiring Example
20
RS-232 Wiring Example with Handshaking
21
RS-232 Basic 3-Wire Example
21
Connecting a 9-Way Socket to the SDM-SIO1A for RS-232 Devices
22
Programming
23
Crbasic Instructions
23
Serialopen()
23
Communications Port Parameters RS-232
24
Communications Port Parameters RS-485 Full Duplex
24
Communications Port Parameters RS-485 Half Duplex
25
Communications Port Parameters RS-232 Receive-Only Mode
25
Serialclose()
26
Serialin()
26
Serialout()
26
Serialinblock
27
Serialoutblock
27
Serialinchk
27
Serialinrecord
27
Serialflush
27
Example Datalogger Programs
27
Example Using RS-232 Mode
28
RS-232 Mode Example
28
Example Using RS-485 Mode
29
RS-485 Mode Example
29
7 Operation
30
Configuring Handshaking and Receive-Only Modes
30
Using RTS/CTS and Automatic Handshaking
30
RS-485 Half-Duplex Mode
30
Using the RS-232 Link in Receive-Only Mode
31
Power Conservation
31
Schematic
31
8 Troubleshooting and Maintenance
32
Troubleshooting
32
RS-485 Internal Circuit Diagram
32
Maintenance
33
Upgrading the Operating System
34
Operating System Signature Errors
34
Checking the Operating System Version and Signature
34
Checking the Operating System Version and Signature
35
Using the Handshaking Lines for General Input/Output
37
The Input Pin (Cts/Pin 11
37
The Output Pin (Rts/Pin 8
38
Matching SDM-SIO1A Connections to an
39
Sdm-Sio1
39
Campbell SDM-SIO1A Instruction Manual (36 pages)
Serial Input/Output Module
Brand:
Campbell
| Category:
Control Unit
| Size: 1.26 MB
Table of Contents
Table of Contents
7
Introduction
9
Specifications
10
Supported Data Rates and Protocols
10
Electrical Parameters
11
SDM-SIO1A Current Consumption
11
SDM-SIO1A Voltage Specifications
12
EMC Compliance
12
Temperature and Humidity Ranges
12
Physical Parameters
13
Datalogger Compatibility
13
Installation
13
Connections
14
Safety Considerations
17
Examples for Connecting the SDM-SIO1A to Other Equipment
17
RS-485/RS422 Full Duplex, One to One Connection Example
17
RS-485 Multi Unit / in Line Example
18
RS-485 Half Duplex Wiring Example
18
RS-485 Internal Circuit Diagram
19
RS-232 Wiring Example with Handshaking
20
RS-232 Basic 3-Wire Example
20
Connecting a 9 Way Socket to the SDM-SIO1A
21
Power Conservation
21
Programming the Datalogger
22
Special Information about the Serial I/O Crbasic Commands When Used with the SDM-SIO1A
22
Serialopen
22
Communications Port Parameters RS-232
23
Communications Port Parameters RS-485 Full Duplex
23
Serialclose
24
Communications Port Parameters RS-485 Half Duplex
24
Communications Port Parameters RS-232 Receive Only Mode
24
Serialin
25
Serialout
25
Serialinblock
25
Serialoutblock
25
Serialinchk
26
Serialinrecord
26
Serialflush
26
Serial Input Errors
26
Configuring Handshaking and Receive Only Modes
26
Using RTS/CTS and Automatic Handshaking
26
RS-485 Half-Duplex Mode
27
Using the RS-232 Link in Receive Only Mode
27
Example Datalogger Programs
27
Firmware Upgrades and Flash Signature Errors
30
Upgrading the Firmware
30
Firmware Signature Errors
30
Checking the Firmware Version and Signature
30
The Input Pin (Cts/Pin 8
33
The Output Pin (Rts/Pin 9
34
Advertisement
Advertisement
Related Products
Campbell SDM-SI01A
Campbell SDM-SI04A
Campbell SDM-IO16
Campbell SDM-CD16
Campbell SDM-SW8A
Campbell SDM-SIO4
Campbell SDMS40
Campbell SDM-SIO1
Campbell SDM-SIO4A
Campbell SDMS-30
Campbell Categories
Measuring Instruments
Accessories
Modem
Weather Station
Recording Equipment
More Campbell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL