2.0
X-Board-UPA is an Evaluation Board (only for development) for VGA,
SVGA, XGA type TFT flatpanels to Kontron JILI interface with digital output
option.
CAUTION : Don´t connect this cable to a JILI Interface with LVDS output!
3.0
The X-Board-UPA is configured with +3,3V DC for the flat panel power
supply and +12V DC for the backlight power supply.
3.1

Configuration:

Dip 1
Dip 2
Dip 3
Dip 4
Dip 5
Dip 6
3.2
Configuration:
Dip 1
Dip 2
Dip 3
Dip 4
Dip 5
Dip 6
08.09.2004

Technical Information Summary

This can cause permanent damage to all connected devices!
Configuration
Configuration SW1
Function:
Inverts the Data Enable signal
ON = not invert, OFF = invert
Inverts the V-Sync signal
ON = not invert, OFF = invert
Inverts the Panel Data Clock signal
ON = not invert, OFF = invert
Inverts the H-Sync signal
ON = not invert, OFF = invert
Select Data mapping
ON = U5 active, OFF = U6 active
Not function
Configuration SW2
Function:
Programmable strobe select, only for LVDS output
ON = Rising edge strobe, OFF = Falling edge strobe
Vertical display mode select signal, only for X7
ON = U/D low, OFF = U/D high
Horizontal display mode select signal, only for X7
ON = R/L low, OFF = R/L high
VGA/QVGA mode select signal, only for X7
ON = Q/V low, OFF = Q/V high
Power for serial eeprom (JILI File)
ON = enable eeprom, OFF = disable eeprom
Power for D/A converter (Backlight dimming control, only for X9)
ON = enable D/A converter, OFF = disable D/A converter
X-BOARD-UPA
Kontron Embedded Modules GmbH
Flatpanel Solutions
Marschnerstieg 7
22081 Hamburg / Germany
Fon: +49 (0)40 20 00 90-0
Fax: +49 (0)40 20 00 90-10
http://www.kontron-emea.com/flatpanel
4