Appendix D: Applications and Switch Administration
Page D-28
Generic 2 System Administration
For data calls that originate on a Generic 2, the tone detector must
be administered. This is done by creating a special trunk group. If
this is the first data application on the switch, then this trunk
group must be created using PROC 100, Word 1 (Screen D-13). In
this case the trunk group is 100.
PROC 100 Word 1 (Screen D-13) is used to create a special
trunk group. The following fields must be populated as
indicated:
Field 1 (Trunk Group): 100. This is the trunk group for the
tone detectors.
Field 6 (Trunk Type): 100. To indicate that this is a tone
detector trunk group.
Once this trunk group is created, no further administration for
tone detectors is needed for additional stations.
ENHANCED MODE - PROCEDURE:
1.
Trunk Group: [100]
DIAL ACCESS CODE/TRUNK ID CODE
2.
Digit 1: [1]
3.
Digit 2: [0]
4.
Digit 3: [0]
5.
Digit 4: [-]
6. Trunk Type: [100]
7.
Dial Access Restriction: [0]
8.
Personal CO Line Appearance: [0]
9. Public Network Access/Egress: [0]
DISPLAY ONLY
10.
Signaling Type: [0]
Generic 2 Tone Detector Administration
PROC 150 is required to install the tone detector circuits.
DEFINITY
Communications System
DEFINITY High Speed Link
100, WORD: 1
SCREEN D-13
User´s Guide