Chapter 4-5-4
Let create Servo Program
• Create CW_RUN and CCW_RUN drive
Step
Explanation
1
SPED(885)
Port is #0 as when we do wiring on
the PLC
For SPED Instruction, Right Click on
the Instruction SPED(885) and
click Instruction Help
For Port setting, Check CP1E
Manual (W480-E1-05), page 12-4
Port
W480-E1-05, Page 12-4
For CIO100.00, port is "0"
For CIO100.01, port is "1"
For CIO100.02, port is "2"
For CIO100.03, port is "3"