High-Speed Counter and Pulse Output

8.4.3.4 F167_PulseOutput_Reset, Target Value Match OFF

If the elapsed value matches the target value of the pulse output channel, the specified output
immediately turns to FALSE.
Pulse output characteristics
0
-200
2
3
4
10000 Target value
1
Elapsed value of pulse output
2
Execution condition
3
"Output control active" flag
PLC output
4
The PLC output turns to FALSE when the elapsed value matches the target value. In addition,
the "Output control active" flag turns to FALSE and the instruction is deactivated.
REFERENCE
Please refer to the FPWIN Pro online help for details and a programming
example.