1:1 Communication; 1:1 Communication With Micro-Imagechecker - Panasonic FP0R User Manual

Hide thumbs Also See for FP0R:
Table of Contents

Advertisement

"transmission done" flag is FALSE.)
5. When the specified number of bytes has been sent, the "transmission done" flag turns
to TRUE.
6. Now, F159_MTRN can be executed again. When F159_MTRN is executed:
- Steps 1 to 5 are repeated. This time, the characters c, d, and e are sent.

7.6.6 1:1 Communication

System register settings
By default, the COM port is set to MEWTOCOL-COM mode. For 1:1 program controlled
communication, the system registers should be set as shown below.
Settings for COM port 1 (or TOOL port)
No.
Name
412
COM port 1 - communication mode
413
COM port 1 - communication format
415
COM port 1 - baud rate
416 (420) COM port 1 - receive buffer starting address 0–32764 (factory setting: 0) (see note)
417 (421) COM port 1 - receive buffer capacity
NOTE
When using C10, C14, or C16, the range is 0–12312.

7.6.6.1 1:1 Communication with Micro-Imagechecker

The FP0R and Micro-Imagechecker A100/A200 are connected using an RS232C cable. The
results of the scan are stored in the data registers of the FP0R.
Communication mode:
Program controlled
communication
PLC
1:1 communication between the FP0R and a Micro-Imagechecker
After the scan start code "%S
returned from the Micro-Imagechecker as the response.
Start command "%S C R " is sent
Scan result "1012345 C R " is received
C
" has been sent from the FP0R side, the scan result is
R
Set value
Program controlled
Data length:
7 bits/8 bits
Parity:
None/Odd/Even
Stop bit:
1 bit/2 bits
End code:
CR/CR+LF/None/ETX
Start code:
No STX/STX
2400–115200bit/s
0–2048 words (factory setting: 2048 words)
Communication mode:
Normal mode
Micro-Imagechecker
A200/A100
Communication
143

Advertisement

Table of Contents
loading

Table of Contents