SMC Networks ISA3 Series Operation Manual page 81

Digital gap checker pressure switch
Hide thumbs Also See for ISA3 Series:
Table of Contents

Advertisement

OUT2 output check
Press the UP or DOWN button to select OUT2 output
check.
In the SIO mode, when the SET
button is pressed, the screen
will return to the output check
screen.
To finish this mode, return the
output to [n] (normal output) and
press the SET button. Then the
mode will return to function
selection mode.
Distance switch output 1
Press the UP or DOWN button to select
forcibly output ON/OFF to check the
output condition.
: Bit offset: 0 in the process data will change to 0 (Forcibly output OFF)/
Press the SET button to set.
Distance switch output 2
Press the UP or DOWN button to select
forcibly output ON/OFF to check the
output condition.
: Bit offset: 1 in the process data will change to 0 (Forcibly output OFF)/
Press the SET button to set.
In IO-Link communication mode, press the
SET button to move on the next confirmation.
During the IO-Link communication, it is possible
to check the process data output operation.
1 (Forcibly output ON).
1 (Forcibly output ON).