3 Step Setting Mode

■3 step setting mode
In this mode, the set values can be input in just 3 steps.
Use this mode if the product is to be used straight away, after changing only the set values.
(Main display shows the switch output mode (ON/OFF))

■Preparation before setting

(1) Supply pressure to the product. (100 to 200 kPa)
(2) Insert a acceptable clearance gauge between the detection surface and the workpiece.
Alternatively, place a sample workpiece (non-defective workpiece) on the detection nozzle.
<Operation>
[3 step setting mode (hysteresis mode)]
In the 3 step setting mode, the set value (P_1 or n_1) and hysteresis (H_1) can be changed. Set the items
on the sub display (set value or hysteresis) with the UP or DOWN button. When changing the set value,
follow the operation below. The hysteresis setting can be changed in the same way.
(1) Press the SET button once when the item to be changed is displayed on the sub display.
The set value on the sub display (right) will start flashing.
-48-