SMC Networks ISA3 Series Operation Manual page 69

Digital gap checker pressure switch
Hide thumbs Also See for ISA3 Series:
Table of Contents

Advertisement

•Level bar display
It is possible to visually display the current detection distance (clearance guideline) on the sub display.
: The level bar is not displayed for the pressure value on the SUP port side and OUT port side.
9 level display
The switch point value bar is only displayed in hysteresis mode.
In window comparator mode, error output and switch output off setting, the switch point value bar will not be
displayed. Only the level meter is displayed.
Boundary value of the switch point value bar and level bar
In hysteresis mode
Hysteresis mode varies depending on the switch point.
Relationship between boundary value and display value of the level bar/switch point value bar and process data
Distance type
ISA-F
Display
ISA3-G
value
ISA3-H
ISA3-F
ISA3-G
Process
data
ISA3-H
Distance type
ISA-F
Display
ISA3-G
value
ISA3-H
ISA3-F
ISA3-G
Process
data
ISA3-H
: The value in the brackets in level 2 shows the boundary value.
Level 1
Level 2
60 or less
(60 to 36)
300 or less
(300 to 176)
Constantly
500 or less
ON
(500 to 351)
3000 or less
(3000 to 1751)
2500 or less
(2500 to 1751)
Level 6
Level 7
X+15
X+10
(20 to 16)
(15 to 11)
X+75
X+50
(100 to 76)
(75 to 51)
X+150
X+100
(200 to 151)
(150 to 101)
X+750
X+500
(1000 to 751)
(750 to 501)
-68-
Level 3
Level 4
X+30
(35 to 31)
(30 to 26)
X+150
(175 to 151)
(150 to 126)
X+300
(350 to 301)
(300 to 251)
X+1500
X+1250
(1750 to 1501)
(1500 to 1251)
Level 8
Level 9
X+5
(10 to 6)
(5 to 0)
X+25
(50 to 26)
(25 to 0)
X+50
(100 to 51)
(50 to 0)
X+250
(500 to 251)
(250 to 0)
4
How to use
Level 4
X+25
X+20
(25 to 21)
X+125
X+100
(125 to 101)
X+250
X+200
(250 to 201)
X+1000
(1250 to 1001)
Weight
X
5
X
25
X
50
X
250
No.PS※※-OMW0009-A