SMC Networks ISA3 Series Operation Manual page 54

Digital gap checker pressure switch
Hide thumbs Also See for ISA3 Series:
Table of Contents

Advertisement

■Table of default settings
The default setting is as follows.
If no problem is caused by this setting, keep these settings.
To change a setting, enter function selection mode.
Function
number
Unit selection
F0
Switch output specifications
Output item
Output mode
Reversed output
F1
Switch point
Hysteresis
Display colour
Output item
Output mode
Reversed output
Pressure setting
F2
Hysteresis
Response time
Display colour
F6
Display value compensation
F10
Sub display setting
F14
Zero cut-off setting
F80
Display off mode setting
Security code selection under key lock
F81
mode
F90
Set all functions
F95
Calibration
F98
Forced output
F99
Reset to default settings
Function
-53-
Label
Default Settings
Unit
[kPa]
NorP
[PnP]
oUt1
[diSt] Gap distance setting
ModE
[HYS] Hysteresis mode
1ot
[1_n] Reversed output
n_1
ISA3-F: [20], ISA3-G: [50], ISA3-H[50]
H_1
ISA3-F: [3], ISA3-G: [20], ISA3-H[20]
[1SoG] Green when ON, Orange when OFF
CoL
(Linked to OUT1)
oUt2
[E_Pr] OUT port pressure detection
ModE
[Wind] Window comparator mode
2ot
[2_P] Normal output
EP2L
[25.0] kPa
EP2H
[50.0] kPa
EH2
[5.0] kPa
EdH2
[1.00] s
EdL2
[1.00] s
[1SoG] Green when ON, Orange when OFF
CoL
(Linked to OUT1)
FSCd
[0.0] Compensation value: 0.0
SUb
[Std] Standard
ISA3-F: [0.0]%, ISA3-G: [6.0]%,
Cut
ISA3-H: [10.0] %
diSP
[on] Normal operation mode
Pin
[oFF] OFF
ALL
[oFF] Set all functions OFF
CAL
[oFF] Not calibrated
tESt
[n] No forced output
ini
[oFF] Not reset
4
How to use
No.PS※※-OMW0009-A