Air suction filter

Advertisement

<Element Replacement >
1. Stop operation and reduce the filter's internal pressure to atmosphere.
2. Loosen the stop pin and open the cover.
3. Hold the knob on the top of the element and take it out.
4. Check the gasket for damage, deformation, or swelling. If any fault is found, replace the gasket with
a new one.
5. Replace the element with a new one in the reverse order.
Note that the cover cannot be closed if the element is inserted into the case in incorrect orientation.
6. Close the cover and tighten the stop pin firmly. [Tightening torque: 1.2N・m +/-10%]
7. After checking that no leakage is found from each part, start the actual operation.
Cover
Procedure 2
Gasket
Stop pin
Procedure 2
Procedure 3
Element
-11-
Procedure 6
Procedure 5