2-2 Specifications
Specifications
Fluid
Operating pressure
Vacuum release pressure
Operating and ambient
temperature range
Filtration
Element replacement
differential pressure
Note) Alcohol, acetone, etc. also cause damage, so be sure for the product not to be close to them.
2-3 Dimensions
1) Single unit
This product cannot be used in an environment
Air, Nitrogen
exposed to chemicals.
It may cause damage to the body.
-100~0kPa
Pressurised condition cannot be kept.
MAX.0.5MPa
Do not use it in a line that is kept pressurized because
it could cause the body to break.
o
o
5
C to 60
C
30µm
Filtering efficiency 95%
20kPa
Note) The above diagram is for ZFA200.
The bracket location shows L side.
Model
-8-
Remarks
Note)
Symbol
Port size
ZFA100
1/8
ZFA200
1/4
A
B
-
18
20
28
Need help?