5

Calibration

Calibration procedures vary depending on application scenarios. The XIO supports the same calibration
utility as other Totalflow devices.
Calibration depends on where the involved applications are in operation and the communication method
between the XIO and the remote controller. The table below describes where the calibration must be
performed from per application scenario. The table also details where the calibration files are stored.
IMPORTANT NOTE: I/O calibration (shown in the last row) can be performed from either the
XIO or the RMC. When calibration is done from the XIO, there is a pop-up message to notify the
user that the IO point they are calibrating may be used in a tube and if that is the case,
calibration should be done from the RMC instead. Regardless of where the calibration takes
place, I/O calibration files are stored on the XIO. The calibration method is the same from XIO
or RMC.
Figure 5-1: Calibration per application scenario
Application
Physical
Location
Comm (XMV
XIO
Interface)
Comm (XMV
XIO
Interface)
Comm (XMV
XIO
Interface)
Comm (XMV
RMC
Interface)
I/O System
XIO
(TFIOs)
Application
Application
Location
Exported
RMC
Yes
XIO
Yes
XIO
No
RMC
No
XIO
Yes
Communication
Calibration
Method
File
Location
Ethernet-Serial
RMC
Passthrough
XIO Interface
XIO
Local serial
XIO
Local serial
RMC
XIO Interface
XIO
XIO USER MANUAL | 2106424MNAA | 97
Calibration
from
device
RMC
RMC
XIO
RMC
RMC/XIO