connecting to the common network the switched-mode interfaces provide. See the logical equivalent of
this configuration in
Figure
Figure 10-5: Local access by host – supported physical connections (daisy-chain topology)
Legend: Local access by host – supported physical connections (daisy chain topology)
ID
Name
1
XIO-2 in the daisy chain
2
XIO-1 in the daisy chain
Figure 10-6
shows the logical network equivalent to the connections shown in
system with PCCU (1) can establish connections to each daisy-chained device on the same network (3).
Each device must have an IP address with the same subnet assigned to the network. The host must also
have that same subnet in its IP address. Note that connections lines on diagrams are independent logical
TCP/IP based connections to each device (from a PCCU instance for each). The host connects to any
available Ethernet port on any of the XIOs (physical connection not shown).
10-6.
ID
Name
3
RMC-100
4
Customer (TCP/IP) network
ID Name
5
Host system with PCCU: local access
through XIO-1(B1) or XIO-2(B2).
Figure 10-5
XIO USER MANUAL | 2106424MNAA | 185
above. A local