LowerLimit:C
062
Sets Development Potential (Lower Limit) (C).
LowerLimit:M
063
Sets Development Potential (Lower Limit) (M).
LowerLimit:Y
064
Sets Development Potential (Lower Limit) (Y).
Current:K
101
Displays Development Potential: Current Value (K) according to paper.
Current:C
102
Displays Development Potential: Current Value (C) according to paper.
Current:M
103
Displays Development Potential: Current Value (M) according to paper.
Current:Y
104
Displays Development Potential: Current Value (Y) according to paper.
[LD Power :Set]
3623
Displays LD power decided Procon.
Line Width Adj.:K
051
Sets Line Width Adj. (K) [Operator Adjustment Item].
Line Width Adj.:C
052
Sets Line Width Adj. (C) [Operator Adjustment Item].
Line Width Adj.:M
053
Sets Line Width Adj. (M) [Operator Adjustment Item].
Line Width Adj.:Y
054
Sets Line Width Adj. (Y) [Operator Adjustment Item].
*ENG
[0 to 400 / 200 / 1V/step]
*ENG
[0 to 400 / 200 / 1V/step]
*ENG
[0 to 400 / 200 / 1V/step]
*ENG
[0 to 800 / 0 / 1V/step]
*ENG
[0 to 800 / 0 / 1V/step]
*ENG
[0 to 800 / 0 / 1V/step]
*ENG
[0 to 800 / 0 / 1V/step]
*ENG
[20 to 120 / 53 / 1um/step]
*ENG
[20 to 120 / 51 / 1um/step]
*ENG
[20 to 120 / 51 / 1um/step]
*ENG
[20 to 120 / 51 / 1um/step]
SP3-XXX (Process)