Latest:L:BE
Displays scanning values of White level peak (L side/BLUE/EVEN Pixel) for LED light
quantity adjustment.
011
Scanning levels of White basis board will be displayed when scanner powers on and LED
light source lighting duty (PWM) is adjusted.
When LED light quantity does not complete, SC102-00 is given.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
Latest:L:BO
Displays scanning values of White level peak (L side/BLUE/ODD Pixel) for LED light
quantity adjustment.
012
Scanning levels of White basis board will be displayed when scanner powers on and LED
light source lighting duty (PWM) is adjusted.
When LED light quantity does not complete, SC102-00 is given.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4852
[LED White Level Peak Read]
Factory Setting:F:RE
Display/Saves White level peak scanning value (F side/RED/EVEN) for factory light
001
quantity adjustment of LED.
Factory scanning value for white level peak from main unit warranty process.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
Factory Setting:F:RO
Display/Saves White level peak scanning value (F side/RED/ODD) for factory light
002
quantity adjustment of LED.
Factory scanning value for white level peak from main unit warranty process.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
Factory Setting:F:GE
Display/Saves White level peak scanning value (F side/GREEN/EVEN) for factory light
003
quantity adjustment of LED.
Factory scanning value for white level peak from main unit warranty process.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
*ENG
[0 to 1023 / 0 / 1digit/step]
*ENG
[0 to 1023 / 0 / 1digit/step]
*ENG
[0 to 1023 / 0 / 1digit/step]
*ENG
[0 to 1023 / 0 / 1digit/step]
*ENG
[0 to 1023 / 0 / 1digit/step]
SP4-XXX (Scanner)
181