Ricoh MP C6502SP System Maintenance page 34

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

1. Main SP Tables-3
[Vsg Adj OK?]
Displays Vsg Adjustment Execution Result. (SP is assigned to be compatible with common
model series)
• Left digit: TM/P sensor (R)
• Right digit: TM/P sensor (L)
Displays result by each sensor from left in R, then L order.
Code
0
3323
1
2
3
4
5
9
001 History:Latest
002 History:Latest2
003 History:Latest3
004 History:Latest4
005 History:Latest5
006 History:Latest6
007 History:Latest7
008 History:Latest8
009 History:Latest9
010 History:Latest10
3330
[ID.Sens Coef :Disp]
32
Result
Did not EXEC.
Succeed
ID sensor proofread error
Offset voltage error
LED Ampere Max. error.
ID sensor output error.
Kill
(SP default)
-
Out of range from Vsg= Vsg_reg(target value)
±x.x[V/step]
Voffset_reg>Max. or Voffset_dif>Max.
Ifsg>Max.
Vsg< Vsg_reg(error)
Kill by error of door open, power off.
*ENG
[0 to 999 / 0 / 1/step]
*ENG
[0 to 999 / 0 / 1/step]
*ENG
[0 to 999 / 0 / 1/step]
*ENG
[0 to 999 / 0 / 1/step]
*ENG
[0 to 999 / 0 / 1/step]
*ENG
[0 to 999 / 0 / 1/step]
*ENG
[0 to 999 / 0 / 1/step]
*ENG
[0 to 999 / 0 / 1/step]
*ENG
[0 to 999 / 0 / 1/step]
*ENG
[0 to 999 / 0 / 1/step]
detail

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents